dev.cesglobal.com

Childress engineering

Expert Witness

Our Services

Expert Witness

At CES, we provide expert witness services in engineering to support legal cases and dispute resolution. Our experienced professionals bring a wealth of knowledge in various engineering disciplines, offering impartial analysis and testimony in court. We assist attorneys, clients, and insurance companies by delivering detailed reports and clear explanations of complex engineering concepts. Whether it involves construction defects, structural failures, or compliance issues, our goal is to provide credible insights that help clarify technical matters and inform judicial proceedings. Trust us to deliver accurate, reliable, and objective evaluations to support your case effectively.

Area we cover

Our areas of expertise include:

  • Custom System Design Assistance
  • Project Phase Consulting Assistance
    • Schematic Design
    • Design Development
    • Construction Documents
    • Specification Writing
    • Mock-Up Testing
    • Construction Administration
    • QAQC Inspections and Field Testing
  • Building code and ADA code interpretation
  • Forensic services and expert witness testimony
  • Main-frame structural evaluations
  • Building envelope structural and roofing & waterproofing evaluation
  • Specialty structures, including handrail, guardrail and structural glass floor systems
  • Third party peer review
  • Remedial construction design
  • Property condition assessments

Our Services

Curious about our services? Take a look and see how we can help you achieve your goals.

Consulting Design Services:

  • Custom Glass Curtainwall and Window Wall Systems
  • Structural Glass Systems
  • Operable Window Systems
  • Skylights and Canopies
  • Handrails and Guardrail Systems
  • Structural Glass Floor Systems
  • Louver Systems
  • Retrofit Curtainwall Systems
  • Granite and Marble Facades
  • Masonry Facades
  • Precast Concrete
  • Aluminum and Composite Panel Systems
  • Stucco and EIFS Systems
  • Custom Exterior Skin Systems
  • Light-Gauge Metal Design Back-Up Systems
  • QAQC Quality Assurance/Quality Control

Third Party Peer Review:

  • Architectural Drawings
  • Project Specifications
  • Engineering Calculations
  • Shop Drawing Review & Submittals
  • Mock-Up Test Witnessing

Building Code and Accessibility Code interpretation:

  • Compliance certification
  • Research

Roofing & Waterproofing Evaluations:

  • Condition Assessment Surveys
  • Uplift testing FM-152
  • Infrared scans
  • Analysis for code update requirements
  • Remedial roof designs and construction documents

Remedial Construction Design:

  • Bidding Documents
  • Budgetary Estimates
  • Construction Documents
  • Construction Project Management
  • Quality Assurance Observations

Forensic

  • Structural Design & Failure Investigation
  • Roof System Design & Failure Investigation
  • Building Envelope Design & Failure Investigation
  • Life Safety observations and recommendations
  • Catastrophic building failures resulting from storm, fire, wind, earthquake and/or water damage
  • Permit assistance

Main-Frame Structural Evaluations:

  • Steel Structures
  • Concrete Structures
  • Wood Structures
  • Tilt Wall Structures
  • Concrete Masonry Structures

Field Testing:

  • AAMA 501.2-03 Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems
  • AAMA 502-02 Voluntary Specification for Field Testing of Windows and Sliding Glass Doors
  • AAMA 503-3 Voluntary Specification For Field Testing of Storefronts, Curtain Walls And Sloped Glazing Systems
  • ASTM E-283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across Specimen
  • ASTM E330 Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference
  • ASTM E 331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference
  • ASTM E 783 Standard Test Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors
  • ASTM E 1105 Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure
  • ASTM E 546 Standard Test Method for Frost/Dew Point of Sealed Insulating Glass Units
  • ASTM E 2353 Standard Test Method for Performance of Glass in Permanent Glass Railing Systems, Guards, and Balustrades
  • ASTM C 1601 Standard Test Method for Field Determination of Water Penetration of Masonry Wall Surfaces

Property Condition Assessments:

  • ASTM E 2018 Standard Guide for Property Condition Assessments: Baseline Property Condition Assessment Process
  • Field inspections services

Expert Witness Projects

Contact Us

Have a question, comment, or need assistance? Feel free to reach out to us. Our team is dedicated to providing timely and helpful responses.

Contact US:

Address: 2505 N. Plano Road Suite 400, Richardson, Texas 75082.

E-Mail:
dvega@cesglobal.com

Phone:
214-451-6630

Childress Engineering Services is a Childress Company which encompasses many entities around the world that help us serve our clients.